Quality Audit for Telecom Towers
|
Proto Assembly Inspection
- Control Dimension
- Dimension of members and plates as per drawing
- Welding quality
- Member arrangement as per drawing
- Fixing of bolts
- Verification of material test reports
- Fixing of accessories like ladder, cable tray, rest platform, working platform & antenna mounts
Fabrication Inspection (sample check)
- Material inspection randomly (straightness of members, size & thickness of members)
- Verification of material test reports
- Sample test of material (if required)
- Dimension of members and plates as per drawings
- Quality of welding
- Quality of galvanizing
Tower Foundation Inspection
- Excavation verification
- Dimension verification
- Quality and Quantity verification of material procured
- Reinforcement verification
- Grade of concrete
- Checking of concrete thickness in foundation pad and chimney
- Alignment of column
- Template fixing
- Verification test reports
Tower Acceptance Test (post erection)
- Tower verticality
- Verification of Grouting at underside of base plate
- Checking of pedestal / base plate level difference
- Verification of items at tower base plate level.
- Usage of required grade of bolts,nuts & washers
- Fixing of all members (checking of member connectivity, missing / swapped members, straightness, etc)
- Fixing and Tightening of bolts & nuts
- Checking of gaps, rusted items, etc
- Fixing of ladder, platforms & antenna mounts
- Ensuring galvanization & painting
- Checking of accessories like lightening arrestor, aviation lamp etc.
- Creation of site data base helpful from tower maintenance perspective
Field Services
Tower Foundation Audits (TFA) & Tower Acceptance Test (TAT)
- Bharti Airtel Limited – Pan India
- Reliance Telecom Ltd – TAT in all circles
- Tata Teleservices – TFA in Few Circles
- Idea – TAT & TFA in Few Circles
- Vodafone – TAT in Few Circles
- Quipo – TAT in all Circles
- Reliance Communications – TAT in all Circles
- Indus – Share Holders Verification Audit in all Circles
|
|  |
|
|